Sample Record

DIME Sample ID 2026-05-20-4

Project Information

Project IdentifiersProject ID: 1002077
DEA: 033H5904
EFIS: 0318000017
DIST-CO-RTE-PM03-PLA-80-R26.3/R55.2
Award Date01/08/2026
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/07/2026)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date05/20/2026 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testingNot set Sample typeQuality Control
A brief description of the sample#7 x 4' diameter welded hoops The quantity of what the sample constitutes135 Hoops
From where was the sample collectedFabricator First name of sampler or witnessed byJacob
Last name of sampler or witnessed byGarcia Title of samplerQuality Assurance Inspector
Telephone number of sampler7606866753 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTNT Rebar
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL169-067-26
Structure unique identifier Structure name
Bid Item124 - BAR REINFORCING STEEL (BRIDGE)

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1202076697
Hoop Manufacturer Lot Number(s)Lot 1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop4'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
No results found.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments