Sample Record

DIME Sample ID 2026-05-17-9

Project Information

Project IdentifiersProject ID: 1000259
DEA: 050N74V4
EFIS: 0522000043
DIST-CO-RTE-PM05-SB-101-9.2/9.7
Award Date02/08/2024
Closeout DateNot set
Work DescriptionNot set
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN SANTA BARBARA COUNTY AT MONTECITO FROM 0.2 MILE NORTH OF SHEFFIELD DRIVE UNDERCROSSING TO 0.3 MILE SOUTH OF SAN YSIDRO ROAD OVERCROSSING
QA Service Level1 (Verified on 04/15/2024)

Owner Lab

  • CT D05 - Carpinteria Field Laboratory

Sample Information

Sample Taken Date05/17/2026 Sample Unique Key9
Date that the sample was received by the laboratory/organization performing the testing05/17/2026 Sample typeQuality Assurance
A brief description of the sampleConcrete Test Sample The quantity of what the sample constitutes100 CY
From where was the sample collectedSupplier First name of sampler or witnessed byMike
Last name of sampler or witnessed byBennett Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Padaro Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number386
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected19296
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-17-9-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteMichael Bennett, CT D05 - Carpinteria Field Laboratory05/17/202605/18/2026
Yes
05/18/2026Public - Test Data Visible
2026-05-17-9-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteMichael Bennett, CT D05 - Carpinteria Field Laboratory05/17/202605/18/2026
Yes
05/18/2026Public - Test Data Visible
2026-05-17-9-3CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodMichael Bennett, CT D05 - Carpinteria Field Laboratory05/17/202605/18/2026
Yes
05/18/2026Public - Test Data Visible
2026-05-17-9-4ASTM C78-18: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)Jesse Gomez, CT D05 - Carpinteria Field Laboratory05/26/202606/16/2026
Yes
06/16/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-05-17-9-1 ASTM C1064-17 (Verified)
DIME Test ID: 2026-05-17-9-2 ASTM C143-20 (Verified)
DIME Test ID: 2026-05-17-9-3 CTM 504-June 2010 (Verified)
DIME Test ID: 2026-05-17-9-4 ASTM C78-18 (Verified)