Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2026-05-06-63

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1001197
DEA: 07319604
EFIS: 0716000025
DIST-CO-RTE-PM07-VEN-1,101-21.3/21.9,R34.9/R36.1
Award Date09/16/2025
Closeout DateNot set
Work DescriptionREMOVE AND CONSTRUCT BRIDGE.
Location DescriptionVENTURA COUNTY ON ROUTE 1 FROM 1.8 MILES NORTH OF ROUTE 1/33 SEPARATION TO 2.0 MILES SOUTH OF A LEASE CANYON ROAD AND ON ROUTE 101 FROM 0.4 MILE NORTH OF DULAH ROAD UNDERCROSSING TO SAN MIGUELITO ROAD UNDERCROSSING
QA Service Level1 (Verified on 07/01/2025)

Sample Information

Sample Taken Date05/06/2026 Sample Unique Key63
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/08/2026
Sample typeVerification A brief description of the sample3/4" HMA A SP RAP 25% LAS 0.5%
The quantity of what the sample constitutesPSU, 4 Bags of Cold feed, 1 Bag of Combined RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byChristopher Last name of sampler or witnessed byHurtado
Title of sampler Telephone number of sampler
Laboratory sample identification0220A-26 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Saticoy Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035, 91-19-0020
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Vulcan -Saticoy
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number220200 SAT VLO Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-06-63-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)DM, CT D08 - Fontana Southern Regional Laboratory05/08/202605/18/2026
Yes
06/22/2026 
2026-05-06-63-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)FO, CT D08 - Fontana Southern Regional Laboratory05/09/202605/19/2026
Yes
06/22/2026 
2026-05-06-63-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)FO, CT D08 - Fontana Southern Regional Laboratory05/09/202605/19/2026
Yes
06/22/2026 
2026-05-06-63-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)FO, CT D08 - Fontana Southern Regional Laboratory05/09/202605/19/2026
Yes
06/22/2026 
2026-05-06-63-5AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)DP, CT D08 - Fontana Southern Regional Laboratory05/16/202605/19/2026
Yes
06/22/2026 
2026-05-06-63-6AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)David Tran, CT D08 - Fontana Southern Regional Laboratory05/09/202605/19/2026
Yes
06/22/2026 
2026-05-06-63-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)DP, CT D08 - Fontana Southern Regional Laboratory05/16/202605/19/2026
Yes
06/22/2026 
2026-05-06-63-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)DP, CT D08 - Fontana Southern Regional Laboratory05/16/202605/19/2026
Yes
06/22/2026 
2026-05-06-63-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJE, CT D08 - Fontana Southern Regional Laboratory05/16/202605/19/2026
Yes
06/22/2026RAP Gradation After Ignition. 
2026-05-06-63-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJE, CT D08 - Fontana Southern Regional Laboratory05/16/202605/19/2026
Yes
06/22/2026Combined aggregate Gradation With RAP Gradation Correction.  

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-05-06-63-1 AASHTO T27-14 (Verified)
DIME Test ID: 2026-05-06-63-2 AASHTO T84-14 (Verified)
DIME Test ID: 2026-05-06-63-3 AASHTO T85-13 (Verified)
DIME Test ID: 2026-05-06-63-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2026-05-06-63-5 AASHTO T304-11 (Verified)
DIME Test ID: 2026-05-06-63-6 AASHTO T176-08 (Verified)
DIME Test ID: 2026-05-06-63-7 AASHTO T335-09r13 (Verified)
DIME Test ID: 2026-05-06-63-8 ASTM D4791-10 (Verified)
DIME Test ID: 2026-05-06-63-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2026-05-06-63-10 CTM 202-November 2011 (Verified)