Sample Record

DIME Sample ID 2026-05-01-53

Project Information

Project IdentifiersProject ID: 1000710
DEA: 100P9244
EFIS: 1023000226
DIST-CO-RTE-PM10-MPA-140-42.0/42.7
Award Date08/22/2025
Closeout DateNot set
Work DescriptionFergusen Slide Rock Avalanche Shed
Location DescriptionMariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal.
QA Service Level1 (Verified on 10/15/2024)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/01/2026 Sample Unique Key53
Date that the sample was received by the laboratory/organization performing the testing05/18/2026 Sample typeQuality Assurance
A brief description of the sample#9 HRC 500/510 Coupler The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byAlexis
Last name of sampler or witnessed byHernandez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHRC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade80 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#9 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)74141308, 73141712 Rebar Heat Number(s)3500043534
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-01-53-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/202606/01/2026
Yes
06/25/2026Public - Test Data Visible
2026-05-01-53-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/202606/01/2026
Yes
06/25/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
M0522-1686 Dime Number 2026-05-01-53 rebar Uniform Elongationpdf05/29/2026   Info
M0522-1686 Dime Number 2026-05-01-53pdf05/29/2026   Info

Test File Attachments


DIME Test ID: 2026-05-01-53-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2026-05-01-53-2 CTM 670-December 2013 (Verified)