Sample Record

Owner Labs

  • CT HQ - QASI Sacramento Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2026-05-15-1

Project Information

Project IdentifiersProject ID: 1001281
DEA: 11430234
EFIS: 1118000029
DIST-CO-RTE-PM11-SD-805-0.1/14.6
Award DateNot set
Closeout DateNot set
Work DescriptionREPLACE CONC PVMT, CONSTRUCT AUX LANE & BIKE TRAIL, ELECT, & LANDSCAPE
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO, CHULA VISTA AND NATIONAL CITY FROM 0.3 MILE SOUTH OF ROUTE 805/5 SEPARATION TO ROUTE 805/15 SEPARATION
QA Service Level1 (Verified on 06/09/2025)

Sample Information

Sample Taken Date05/15/2026 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/20/2026
Sample typeQuality Assurance A brief description of the sample#6 x 2'-6" hoops
The quantity of what the sample constitutes358 pcs From where was the sample collectedFabricator
First name of sampler or witnessed byJoaquin Last name of sampler or witnessed byMoreno
Title of samplerQuality Assurance Inspector Telephone number of sampler9095268064
Laboratory sample identification Linked DIME Sample ID2026-05-15-1
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL161-038-26 Structure unique identifier
Structure name Bid Item185 - BAR REINFORCING STEEL (BRIDGE)

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)034726
Hoop Manufacturer Lot Number(s)Lots 1-3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-05-15-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory05/28/202605/28/2026
Yes
05/28/2026 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-05-15-1-1 CTM 670-December 2013 (Verified)