Sample Record
Owner Lab
- CT - Unassigned/General Field Laboratory
DIME Sample ID 2018-01-18-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212706 DEA: 051J4004 EFIS: 0517000095 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR,SCR-9-11.0, 11.00 |
| Award Date | 09/06/2017 |
| Closeout Date | 09/20/2022 |
| Work Description | Repair Slipout damage by constructing sidehill viaduct |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 09/18/2017) |
Sample Information
| Sample Taken Date | 01/18/2018 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/18/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Resistance Butt Welded Hoops |
| The quantity of what the sample constitutes | 300 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
| Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-103-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 591865 |
| Hoop Manufacturer Lot Number(s) | H01 H02 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 6 |
| Diameter of Hoop | 1'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Evraz |
| Welding Company | Harris Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2018-01-18-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-01-18-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-01-18-2-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-01-18-2-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-01-18-2-5 CTM 670-December 2013 (Verified)