Sample Record

Owner Lab

  • Con-Fab California Corporation - Lathrop

DIME Sample ID 2026-04-30-14

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1001329
DEA: 100X7404
EFIS: 1013000008
DIST-CO-RTE-PM10-CAL-12-17.1/17.5
Award Date09/03/2025
Closeout DateNot set
Work DescriptionBRIDGE REPLACEMENT.
Location DescriptionCALAVERAS COUNTY NEAR SAN ANDREAS FROM 0.2 MILE WEST OF NORTH FORK CALAVERAS RIVER BRIDGE TO 0.2 MILE EAST OF NORTH CALAVERAS RIVER BRIDGE
QA Service Level1 (Verified on 06/16/2025)

Sample Information

Sample Taken Date04/30/2026 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/30/2026
Sample typeQuality Control A brief description of the sample1 cubic foot
The quantity of what the sample constitutes1 cubic foot From where was the sample collectedFabricator
First name of sampler or witnessed byPatrick Last name of sampler or witnessed byWright
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConFab Lathrop Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberL_95M1L_KRC38_PF1
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected14205
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBed 4, 1st Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-04-30-14-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJerry Xiong, Con-Fab California Corporation - Lathrop04/30/202604/30/2026
Yes
05/01/2026 
2026-04-30-14-2ASTM C1611-21: Standard Test Method for Slump Flow of Self-Consolidating ConcreteJerry Xiong, Con-Fab California Corporation - Lathrop04/30/202604/30/2026
Yes
05/01/2026 
2026-04-30-14-3ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodJerry Xiong, Con-Fab California Corporation - Lathrop04/30/202604/30/2026
Yes
05/01/2026 
2026-04-30-14-4ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensJerry Xiong, Con-Fab California Corporation - Lathrop05/01/202605/01/2026
Yes
05/01/2026 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-04-30-14-1 ASTM C1064-17 (Verified)
DIME Test ID: 2026-04-30-14-2 ASTM C1611-21 (Verified)
DIME Test ID: 2026-04-30-14-3 ASTM C231-17a (Verified)
DIME Test ID: 2026-04-30-14-4 ASTM C39-21 (Verified)