Sample Record

DIME Sample ID 2026-04-20-32

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date04/20/2026 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing04/29/2026 Sample typeQuality Assurance
A brief description of the sampleHRC 500/510 Coupler The quantity of what the sample constitutes8
From where was the sample collectedManufacturer First name of sampler or witnessed byTrevor
Last name of sampler or witnessed byShiplee Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHRC
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73140308, 74141308 Rebar Heat Number(s)1202070637
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-04-20-32-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory05/05/202605/05/2026
Yes
05/05/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM5 Couplers rev 2026-04-20-32pdf05/01/2026   Info
26001338.005A_20260420_26-SAC-00604_Metal_DIME ID#2026-04-20-32pdf05/01/2026   Info

Test File Attachments


DIME Test ID: 2026-04-20-32-1 CTM 670-December 2013 (Verified)