Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2026-02-27-49

Project Information

Project IdentifiersProject ID: 1000365
DEA: 033H9014
EFIS: 0323000075
DIST-CO-RTE-PM03-SOL,YOL-50,80,113-Var
Award Date09/27/2024
Closeout DateNot set
Work DescriptionHMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS.
Location DescriptionSOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 09/17/2024)

Sample Information

Sample Taken Date02/27/2026 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/28/2026
Sample typeQuality Control A brief description of the sample4x8 Cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byMitchell Last name of sampler or witnessed byWhitlock
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identification1628930 Set 1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Fairfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSign A7 at STA 294+10, Truck#10077250 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1628930
The truck number from where the sample was collected10077250 The batch plant ticket number from where the sample was collected0
Concrete batch plantCemex The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collected Load #1 Where the material sample would have been placed if not sampled
From Lot No.1 Bag Lot No.1

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-02-27-49-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteMitchell Whitlock, G3 Quality, Incorporated - Cerritos02/28/202604/17/2026
No
 
2026-02-27-49-2CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteMitchell Whitlock, G3 Quality, Incorporated - Cerritos02/28/202604/17/2026
No
 
2026-02-27-49-3CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteMitchell Whitlock, G3 Quality, Incorporated - Cerritos02/28/202604/17/2026
No
 
2026-02-27-49-4CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTravis Van-Y, G3 Quality, Incorporated - Cerritos03/06/202604/17/2026
No
 
2026-02-27-49-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTravis Van-Y, G3 Quality, Incorporated - Cerritos03/13/202604/17/2026
No
 
2026-02-27-49-6CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTravis Van-Y, G3 Quality, Incorporated - Cerritos03/27/202604/17/2026
No
 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-02-27-49-1 CTM 557-June 2020
DIME Test ID: 2026-02-27-49-2 CTM 518-June 2010
DIME Test ID: 2026-02-27-49-3 CTM 556-January 2018
DIME Test ID: 2026-02-27-49-4 CTM 521-June 2020
DIME Test ID: 2026-02-27-49-5 CTM 521-June 2020
DIME Test ID: 2026-02-27-49-6 CTM 521-June 2020