Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2026-04-09-46
Project Information
| Project Identifiers | Project ID: 994366 DEA: 044J9104 EFIS: 0416000010 |
|---|---|
| DIST-CO-RTE-PM | 04-SCL-87-0.0/6.1 |
| Award Date | 04/19/2023 |
| Closeout Date | Not set |
| Work Description | Cold plane AC, paving with RHMA, upgrade median CB and curb ramp. |
| Location Description | CONSTRUCTION ON STATE HIGHWAY IN SANTA CLARA COUNTY IN SAN JOSE FROM ROUTE 85/87 SEPARATION TO 0.1 MILE NORTH OF JULIAN STREET UNDERCROSSING. |
| QA Service Level | 1 (Verified on 04/05/2023) |
Sample Information
| Sample Taken Date | 04/09/2026 | Sample Unique Key | 46 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/21/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/8 X 1 1/4 HDG Hex bolt |
| The quantity of what the sample constitutes | 3 of 500 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
| Title of sampler | QA | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-044-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
|---|---|---|---|
| Heat Number(s) | 1000226162 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | Gr. 5 HX Cap Screw |
| Bolt Length(s) | 1-1/4 | Nut Specification | none |
| Washer Specification | none | Finish | Galvanize |
| Diameter/Size | 3/8 | Bolt Mfg. Lot Number | 26065673 |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) | none |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| No results found. | |||||||||
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||