Sample Record
Owner Lab
- OldCastle Precast, Incorporated - Fontana
DIME Sample ID 2026-03-23-54
Project Information
| Project Identifiers | Project ID: 1001361 DEA: 120M9704 EFIS: 1213000099 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-11.5/12.5 |
| Award Date | 09/25/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS. |
| Location Description | ORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/28/2025) |
Sample Information
| Sample Taken Date | 03/23/2026 | Sample Unique Key | 54 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/23/2026 |
| Sample type | Quality Control | A brief description of the sample | Concrete Cylinders |
| The quantity of what the sample constitutes | 9 cylinders | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Paul Ortega | Last name of sampler or witnessed by | Paul Ortega |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | OLDCASTLE PRECAST | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | UV-247B |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 84964 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | On site next next to the form | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2026-03-23-54-1 ASTM C143-20 (Verified)
DIME Test ID: 2026-03-23-54-2 ASTM C231-17a
DIME Test ID: 2026-03-23-54-3 ASTM C39-21
DIME Test ID: 2026-03-23-54-4 CTM 518-June 2010
DIME Test ID: 2026-03-23-54-5 ASTM C39-18 (Verified)
DIME Test ID: 2026-03-23-54-6 ASTM C1064-17 (Verified)