Sample Record

DIME Sample ID 2017-12-20-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211616
DEA: 050G0404
EFIS: 0500020020
DIST-CO-RTE-PM05-SLO,MON-101-63.2/R69.3,R0.0/R1.9
Award Date11/16/2016
Closeout Date10/29/2020
Work DescriptionROADWAY REHABILITATION AND BRIDGE CONSTRUCTION.
Location DescriptionSAN LUIS OBISPO AND MONTERY COUNTIES NEAR PASO ROBLES FROM 0.5 MILE SOUTH OF SAN MARCOS CREEK BRIDGE TO 0.2 MILE SOUTH OF BRADLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 09/15/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date12/20/2017 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing12/22/2017 Sample typeQuality Assurance
A brief description of the sampleLenton Couplers The quantity of what the sample constitutes4
From where was the sample collectedDistributor First name of sampler or witnessed byJames
Last name of sampler or witnessed byPalmer Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameAlamillo Rebar
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Nucor
Coupler ManufacturerErico Intermediate Assembler or FabricatorUnknown
Rebar Size8 Coupler ModelA2 Lenton
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)L9077, L8942, L9081, L9043 Rebar Heat Number(s)232117, PL16207340
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-12-20-10-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/26/201712/26/2017
Yes
01/02/2018Service SplicePublic - Test Data Visible
2017-12-20-10-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/26/201712/26/2017
Yes
01/02/2018Service SplicePublic - Test Data Visible
2017-12-20-10-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/26/201712/26/2017
Yes
01/02/2018Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-12-20-10-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-20-10-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-12-20-10-3 CTM 670-December 2013 (Verified)