Sample Record

DIME Sample ID 2026-03-31-2

Project Information

Project IdentifiersProject ID: 994901
DEA: 112T3434
EFIS: 1120000081
DIST-CO-RTE-PM11-SD-805-5.1/8.3
Award Date01/29/2024
Closeout DateNot set
Work DescriptionSOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL.
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING
QA Service Level1 (Verified on 03/21/2024)

Owner Lab

  • CT D11 - District 11 Materials Laboratory

Sample Information

Sample Taken Date03/31/2026 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing04/01/2026 Sample typeQuality Assurance
A brief description of the sampleField Sample The quantity of what the sample constitutesField Sample
From where was the sample collectedSource First name of sampler or witnessed byKleinfelder
Last name of sampler or witnessed byKleinfelder Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAssociated Otay
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number556300
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedField Sample Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-03-31-2-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMohammad Abbassi, CT D11 - District 11 Materials Laboratory04/07/202604/07/2026
Yes
04/08/20267 Day, 2890<4000 psi @42 day does not complyPublic - Test Data Visible
2026-03-31-2-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMohammad Abbassi, CT D11 - District 11 Materials Laboratory04/14/202604/14/2026
Yes
04/15/202614 Day, 3710psi< 4000psi @ 42 days, does not complyPublic - Test Data Visible
2026-03-31-2-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMohammad Abbassi, CT D11 - District 11 Materials Laboratory04/28/202604/28/2026
Yes
04/28/202628 Day, 4400psi>4000psi, compliesPublic - Test Data Visible
2026-03-31-2-4CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMohammad Abbassi, CT D11 - District 11 Materials Laboratory05/12/202605/12/2026
Yes
05/12/202642 Day, 5170psi>4000psi, compliesPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-03-31-2-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2026-03-31-2-2 CTM 521-June 2020 (Verified)
DIME Test ID: 2026-03-31-2-3 CTM 521-June 2020 (Verified)
DIME Test ID: 2026-03-31-2-4 CTM 521-June 2020 (Verified)