Sample Record

DIME Sample ID 2026-03-12-61

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000259
DEA: 050N74V4
EFIS: 0522000043
DIST-CO-RTE-PM05-SB-101-9.2/9.7
Award Date02/08/2024
Closeout DateNot set
Work DescriptionNot set
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN SANTA BARBARA COUNTY AT MONTECITO FROM 0.2 MILE NORTH OF SHEFFIELD DRIVE UNDERCROSSING TO 0.3 MILE SOUTH OF SAN YSIDRO ROAD OVERCROSSING
QA Service Level1 (Verified on 04/15/2024)

Owner Lab

  • CT D05 - Carpinteria Field Laboratory

Sample Information

Sample Taken Date03/12/2026 Sample Unique Key61
Date that the sample was received by the laboratory/organization performing the testing03/12/2026 Sample typeQuality Assurance
A brief description of the sample3/4 HMA SP R25 The quantity of what the sample constitutes120 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byJesse
Last name of sampler or witnessed byGomez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Santa Paula
Transportation Laboratory (TL) Number4DS0106 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSide to Side Discharge
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number14342 Lot number1
Sublot number6 Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-03-12-61-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Jesse Gomez, CT D05 - Carpinteria Field Laboratory03/19/202603/23/2026
Yes
03/23/2026Public - Test Data Visible
2026-03-12-61-2AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Jesse Gomez, CT D05 - Carpinteria Field Laboratory03/19/202603/23/2026
Yes
03/23/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-03-12-61-1 AASHTO T27-14 (Verified)
DIME Test ID: 2026-03-12-61-2 AASHTO T176-08 (Verified)