Sample Record
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2026-03-23-2
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 1001955 DEA: 061H6904 EFIS: 0625000252 COOP: NONE |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-190-42.75 |
| Award Date | 07/14/2025 |
| Closeout Date | Not set |
| Work Description | Install Sidehill Viaduct (Bridge No. 46-0285). |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 02/17/2026) |
Sample Information
| Sample Taken Date | 03/23/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/26/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #9 HRC 150 T-Heads |
| The quantity of what the sample constitutes | 4 Samples from lot 1 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | (916) 767-3535 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | HRC Fountain Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-022-26 | Structure unique identifier | |
| Structure name | Bid Item | 5 - BAR REINFORCING STEEL, BRIDGE |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4156199 | Head Manufacturer Lot Number(s) | 400002576123 |
| Rebar Size | #9 | Headed Bar Model Name | HRC 150 T Heads |
| Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
| Head Shape | Square | Rebar Manufacturer | CMC Steel Arizona |
| Head Manufacturer | HRC Fountain Valley | Head Fabricator | HRC Fountain Valley |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Submitted Tests
Test File Attachments
DIME Test ID: 2026-03-23-2-1 ASTM A970-18 (Verified)