Sample Record

DIME Sample ID 2026-03-17-6

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Owner Lab

  • CT D05 - Carpinteria Field Laboratory

Sample Information

Sample Taken Date03/17/2026 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing03/17/2026 Sample typeQuality Assurance
A brief description of the sample1 x 4 PCC Aggregates The quantity of what the sample constitutes 8 CY
From where was the sample collectedSupplier First name of sampler or witnessed byMichael
Last name of sampler or witnessed byBennett Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCEMEX Santa Barbara
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1629003
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31926875
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-03-17-6-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteMichael Bennett, CT D05 - Carpinteria Field Laboratory03/17/202603/17/2026
Yes
03/17/2026Public - Test Data Visible
2026-03-17-6-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteMichael Bennett, CT D05 - Carpinteria Field Laboratory03/17/202603/17/2026
Yes
03/17/2026Public - Test Data Visible
2026-03-17-6-3ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodMichael Bennett, CT D05 - Carpinteria Field Laboratory03/17/202603/17/2026
Yes
03/17/2026Public - Test Data Visible
2026-03-17-6-4CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMichael Bennett, CT D05 - Carpinteria Field Laboratory03/24/202603/24/2026
Yes
03/24/2026Public - Test Data Visible
2026-03-17-6-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersMichael Bennett, CT D05 - Carpinteria Field Laboratory03/17/202604/21/2026
Yes
04/21/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-03-17-6-1 ASTM C1064-17 (Verified)
DIME Test ID: 2026-03-17-6-2 ASTM C143-20 (Verified)
DIME Test ID: 2026-03-17-6-3 ASTM C231-17a (Verified)
DIME Test ID: 2026-03-17-6-4 CTM 521-June 2020 (Verified)
DIME Test ID: 2026-03-17-6-5 CTM 521-June 2020 (Verified)