Sample Record

Owner Labs

  • CT HQ - QASI Bay Area Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2026-03-13-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1001248
DEA: 120K93U4
EFIS: 1224000084
DIST-CO-RTE-PM12-ORA-57,91-13.9/16.1,4.8/6.6
Award Date10/20/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionANAHEIM AND PLACENTIA ON ROUTE 57 FROM WAGNER AVENUE OVERCROSSING TO 0.2 MILE NORTH OF MIRALOMA AVENUE OVERCROSSING AND ON ROUTE 91 FROM 0.1 MILE EAST OF ACACIA STREET UNDERCROSSING TO 0.2 MILE EAST OF LA PALMA AVENUE OVERCROSSING
QA Service Level1 (Verified on 06/16/2025)

Sample Information

Sample Taken Date03/13/2026 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/24/2026
Sample typeQuality Assurance A brief description of the sample1/2" Uncoated Seven Wire Steel Strand for Prestressed Concrete
The quantity of what the sample constitutes20 Strand Packs From where was the sample collectedFabricator
First name of sampler or witnessed byStephen Last name of sampler or witnessed byHaynes
Title of samplerQuality Assurance Inspector Telephone number of sampler5105931179
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePinnacle Prestress, Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB408-008-26 Structure unique identifier
Structure name Bid Item169 - FURNISH PILING (CLASS 200, ALTERNATIVE X)

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S133462-7, S133463-6, S133463-8, S133464-6, S133465-6, S133465-7, S133465-8, S133462-1, S133463-7, S133464-2, S133464-3, S133464-7, S133464-8, S133465-1, S133462-2, S133462-3, S133462-4, S133463-1, S133463-2, S133463-3 Number of Coils20
Group Number Strand Diameter.5 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0546825 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire Products Corporation

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-03-13-6-1ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed ConcreteAndrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory04/06/202604/06/2026
Yes
04/06/2026 

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-03-13-6-1 ASTM A416-18 (Verified)