Sample Record

DIME Sample ID 2026-02-25-19

Project Information

Project IdentifiersProject ID: 1001213
DEA: 11431644
EFIS: 1122000232
DIST-CO-RTE-PM11-SD-78-N17.7
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location DescriptionIN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
QA Service Level1 (Verified on 05/07/2025)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date02/25/2026 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing03/03/2026 Sample typeQuality Assurance
A brief description of the sampleF1554 Gr 55 The quantity of what the sample constitutes8
From where was the sample collectedJob Site First name of sampler or witnessed byCarlos
Last name of sampler or witnessed byFuentes Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBaker Electric
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)NA
Heat Number(s)79015258, 8000027959, 249633 Nut Mfg. Lot Number(s)W000139493
Washer Mfg. Lot Number(s)E6678 Bolt SpecificationF1554 Gr 55
Bolt Length(s)24 Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size3/4 Bolt Mfg. Lot NumberNA
Rocap Test Requirement(s)NA Lubricant Requirements(s)NA
Washer Inner Diameter(s)NA Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-02-25-19-1ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Kevin De Souza, CT HQ - Sacramento Structural Materials Testing Laboratory03/05/202603/05/2026
No

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-02-25-19-1 ASME B1.2-83r17