Sample Record

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

DIME Sample ID 2026-01-20-46

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1001957
DEA: 021K7204
EFIS: 0224000158
DIST-CO-RTE-PM02-SHA-273-5.2/14.5
Award Date11/21/2028
Closeout DateNot set
Work DescriptionBrighter 273 Safety - Install lighting
Location DescriptionIn Shasta County from 0.1 mile North of Anderson Creek bridge in Anderson to 0.1 North of Buenaventura Boulevard in Redding 6/17/24 JC
QA Service Level1 (Verified on 02/17/2026)

Sample Information

Sample Taken Date01/20/2026 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/21/2026
Sample typePreliminary A brief description of the sample2 Bags Rock and Soil
The quantity of what the sample constitutesStructural Section Recommendation From where was the sample collectedSource
First name of sampler or witnessed byDerek Last name of sampler or witnessed bySerna
Title of samplerMREA Telephone number of sampler
Laboratory sample identificationD80134 Linked DIME Sample ID
The fabricator/manufacturer/facility nameDistrict 2 Lab Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedShoulder Slope near PM 10.0
Where the material sample would have been placed if not sampled

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-01-20-46-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJosh Murphy , CT D02 - Redding Northern Regional Laboratory02/09/202602/18/2026
Yes
02/18/2026Public - Test Data Visible
2026-01-20-46-2CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerJosh Murphy , CT D02 - Redding Northern Regional Laboratory02/17/202602/18/2026
Yes
02/18/2026R=71Public - Test Data Visible
2026-01-20-46-3CTM 217-June 2011: Method of Test for Sand EquivalentColt Sweeny, CT D02 - Redding Northern Regional Laboratory02/17/202602/18/2026
Yes
02/18/2026SE=21Public - Test Data Visible
2026-01-20-46-4CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)Colt Sweeny, CT D02 - Redding Northern Regional Laboratory02/10/202602/18/2026
Yes
02/18/2026PI=NPPublic - Test Data Visible
2026-01-20-46-5ASTM D2487-17: Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)Colt Sweeny, CT D02 - Redding Northern Regional Laboratory02/18/202602/18/2026
Yes
02/18/2026A silty gravel with sand, (GM)sPublic - Test Data Visible
2026-01-20-46-6CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and WaterJosh Ferency, CT D02 - Redding Northern Regional Laboratory02/05/202602/18/2026
Yes
02/18/2026pH=6.49, p=10816.Ω∙cmPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-01-20-46-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2026-01-20-46-2 CTM 301-March 2000 (Verified)
DIME Test ID: 2026-01-20-46-3 CTM 217-June 2011 (Verified)
DIME Test ID: 2026-01-20-46-4 CTM 204-June 2010 (Verified)
DIME Test ID: 2026-01-20-46-5 ASTM D2487-17 (Verified)
DIME Test ID: 2026-01-20-46-6 CTM 643-April 2020 (Verified)