Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2026-02-10-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000510
DEA: 060W79U4
EFIS: 0622000189
DIST-CO-RTE-PM06-KER,TUL-99-56.4/57.6,0.0/13.5
Award Date04/10/2025
Closeout DateNot set
Work DescriptionRDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC.
Location DescriptionKERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING
QA Service Level1 (Verified on 08/26/2024)

Sample Information

Sample Taken Date02/10/2026 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/12/2026
Sample typeQuality Assurance A brief description of the sample#6 x 2'-0"
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byAlexis Last name of sampler or witnessed byMillan
Title of samplerCT METS QA INSPECTOR Telephone number of sampler9097569960
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberL191-018-26
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item76 - BAR REINFORCING STEEL (BRIDGE)

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)1201071818
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-02-10-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory02/17/202602/17/2026
Yes
02/17/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM5 Welded Hoops 2026-02-10-1pdf02/13/2026   Info
26001338.005A_20260210_26-SAC-00250_Metal_DIME ID#2026-02-10-1pdf02/13/2026   Info

Test File Attachments


DIME Test ID: 2026-02-10-1-1 CTM 670-December 2013 (Verified)