Sample Record

DIME Sample ID 2017-11-21-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date11/21/2017 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing11/30/2017 Sample typeIndependent Assurance
A brief description of the sampleA706 T-Headed Rebar The quantity of what the sample constitutes4 bars
From where was the sample collectedFabricator First name of sampler or witnessed byKevin
Last name of sampler or witnessed byChurchill Title of samplerIQA Inspector
Telephone number of sampler510-693-3545 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Rbar
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL02
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4070465 Head Manufacturer Lot Number(s)97
Rebar Size#6 Headed Bar Model NameHRC 555
Size of HeadReduced Size - 4x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerCMC Rebar
Head ManufacturerCMC HRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-11-21-5-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/01/201712/01/2017
Yes
12/08/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-11-21-5-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/01/201712/01/2017
Yes
12/08/2017Bar Broke; OK NeckingPublic - Test Data Visible
2017-11-21-5-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory12/01/201712/01/2017
Yes
12/08/2017Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-11-21-5-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2017-11-21-5-2 ASTM A970-15e1 (Verified)