Sample Record

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2026-01-22-10

Project Information

Project IdentifiersProject ID: 1000403
DEA: 120K91U4
EFIS: 1222000031
DIST-CO-RTE-PM12-ORA-91-R9.2/R11.4
Award Date01/03/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING
QA Service Level1 (Verified on 08/19/2024)

Sample Information

Sample Taken Date01/22/2026 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing01/26/2026
Sample typeQuality Assurance A brief description of the sampleHRC 500/510 Couplers
The quantity of what the sample constitutes280 From where was the sample collectedJob Site
First name of sampler or witnessed byJacob Last name of sampler or witnessed byGarcia
Title of samplerQA Inspector Telephone number of sampler7606866753
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHeaded Reinforcement Corporation (HRC) Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL169-017-26 Structure unique identifier
Structure name Bid Item152 - BAR REINFORCING STEEL (BRIDGE)

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHeaded Reinforcement Corporation Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)100022786140 Rebar Heat Number(s)4154542
Rebar Size 2 Coupler Unique IDTP-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-01-22-10-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/28/202601/28/2026
Yes
01/28/2026Public - Test Data Visible
2026-01-22-10-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory01/28/202601/28/2026
Yes
01/28/2026Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-01-22-10-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2026-01-22-10-2 CTM 670-December 2013 (Verified)