Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2025-09-05-102

Project Information

Project IdentifiersProject ID: 1001219
DEA: 021J8904
EFIS: 0221000006
DIST-CO-RTE-PM02-SHA-5-R30.5/R31.0
Award Date07/02/2025
Closeout DateNot set
Work DescriptionREPLACE PAVEMENT AND PLACE POLYESTER CONCRETE OVERLAY.
Location DescriptionSHASTA COUNTY NEAR O\'BRIEN FROM 0.1 MILE SOUTH OF TUNNEL GULCH VIADUCT TO THE O\'BRIEN REST AREA
QA Service Level1 (Verified on 05/05/2025)

Sample Information

Sample Taken Date09/05/2025 Sample Unique Key102
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/05/2025
Sample typeQuality Control A brief description of the sample4 x 8 Concrete Cylinders
The quantity of what the sample constitutes20 From where was the sample collectedJob Site
First name of sampler or witnessed byBrent Last name of sampler or witnessed byVan-Y
Title of sampler Telephone number of sampler
Laboratory sample identification85373-1 TP Set 1 Linked DIME Sample ID
The fabricator/manufacturer/facility namePrecision Concrete Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number85373-1 TP
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected0
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedPrecision Concrete Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-09-05-102-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteBrent Van-Y, G3 Quality, Incorporated - Cerritos09/05/202501/15/2026
No
2025-09-05-102-2CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteBrent Van-Y, G3 Quality, Incorporated - Cerritos09/05/202501/15/2026
No
2025-09-05-102-3CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodBrent Van-Y, G3 Quality, Incorporated - Cerritos09/05/202501/15/2026
No
2025-09-05-102-4CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteBrent Van-Y, G3 Quality, Incorporated - Cerritos09/05/202501/15/2026
No
2025-09-05-102-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersBrent Van-Y, G3 Quality, Incorporated - Cerritos09/05/202501/15/2026
No
2025-09-05-102-6CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTravis Van-Y, G3 Quality, Incorporated - Cerritos09/08/202501/15/2026
No
2025-09-05-102-7CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTravis Van-Y, G3 Quality, Incorporated - Cerritos10/03/202501/15/2026
No

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-09-05-102-1 CTM 557-June 2020
DIME Test ID: 2025-09-05-102-2 CTM 518-June 2010
DIME Test ID: 2025-09-05-102-3 CTM 504-June 2010
DIME Test ID: 2025-09-05-102-4 CTM 556-January 2018
DIME Test ID: 2025-09-05-102-5 CTM 521-June 2020
DIME Test ID: 2025-09-05-102-6 CTM 521-June 2020
DIME Test ID: 2025-09-05-102-7 CTM 521-June 2020