Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2026-01-05-3

Project Information

Project IdentifiersProject ID: 1000777
DEA: 07370404
EFIS: 0720000128
DIST-CO-RTE-PM07-LA-5-R59.5/R73.7
Award Date02/06/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT, PLACE HOT MIX ASPHALT AND INSTALL MGS.
Location DescriptionLOS ANGELES COUNTY FROM LAKE HUGHES ROAD UNDERCROSSING TO 0.7 MILE SOUTH OF VISTA DEL LAGO ROAD OVERCROSSING.
QA Service Level1 (Verified on 11/25/2024)

Sample Information

Sample Taken Date01/05/2026 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/06/2026
Sample typeQuality Control A brief description of the sample4x8 cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byBrenda Last name of sampler or witnessed byAmaya
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identification Linked DIME Sample IDS63C451T1 Set 1
The fabricator/manufacturer/facility nameNational Ready Mix Santa Clarita Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameS/B North Barrier Wall Transition at I-5 Templin Rt Shldr Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS63C451T1
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected0
Concrete batch plantNational Ready Mix The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedS/B North Barrier Wall Transition at I-5 Templin Rt Shldr Where the material sample would have been placed if not sampled
From Lot No.1 Bag Lot No.1

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-01-05-3-1CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteBrenda Amaya, G3 Quality, Incorporated - Cerritos01/05/202601/08/2026
No
2026-01-05-3-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodBrenda Amaya, G3 Quality, Incorporated - Cerritos01/05/202601/08/2026
No
2026-01-05-3-3CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteBrenda Amaya, G3 Quality, Incorporated - Cerritos01/05/202601/08/2026
No
2026-01-05-3-4CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteBrenda Amaya, G3 Quality, Incorporated - Cerritos01/05/202601/08/2026
No

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-01-05-3-1 CTM 518-June 2010
DIME Test ID: 2026-01-05-3-2 CTM 504-June 2010
DIME Test ID: 2026-01-05-3-3 CTM 556-January 2018
DIME Test ID: 2026-01-05-3-4 CTM 557-June 2020