Sample Record

DIME Sample ID 2026-01-06-1

Project Information

Project IdentifiersProject ID: 994443
DEA: 053307C4
EFIS: 0514000028
DIST-CO-RTE-PM05-SLO-41,46-44.5/45.3,54.0/57.8
Award Date02/27/2023
Closeout DateNot set
Work DescriptionWye Segment - Route 41/46 Separation
Location DescriptionNot set
QA Service Level1 (Verified on 12/16/2022)

Owner Labs

  • CT D06 - Millbrook Field Laboratory
  • CT HQ - FFS - Skid Testing

Sample Information

Sample Taken Date01/06/2026 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing01/06/2026 Sample typeAcceptance
A brief description of the sampleSkid Testing Request The quantity of what the sample constitutesBridge- 2 Lanes and shoulders
From where was the sample collectedJob Site First name of sampler or witnessed byCristian
Last name of sampler or witnessed bySuarez Title of sampler
Telephone number of sampler5592594817 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameATKINSON CONSTRUCTION
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier49-0276 L Structure nameCholame Creek Bridge Left
Bid Item96 - STRUCTURAL CONCRETE, BRIDGE (POLYMER FIBER)

Material Information

Material TypeRoadway/Bridge Surface Pavement Surface TypePCC (Portland Cement Concrete)
Type of Traffic Control ProvidedN/A DIST-CO-RTE05-SLO-46
Direction of TravelEast Post Mile
Lanes to be TestedShoulder,Lane #1,Lane #2 Station1356+65.00

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2026-01-06-1-1CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing01/13/202601/13/2026
Yes
01/13/2026BR#49-0277L-APPROACH AND DEPARTURE SLABS BOTH PASSED WITH AN AVG OF .38Public - Test Data Visible
2026-01-06-1-2CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)HARISH THAKUR, CT HQ - FFS - Skid Testing01/13/202601/13/2026
Yes
01/13/2026BR#49-0276L-APPROACH AND DEPARTURE SLABS BOTH PASSED WITH AN AVG OF .39Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2026-01-06-1-1 CTM 342-August 2012 (Verified)
DIME Test ID: 2026-01-06-1-2 CTM 342-August 2012 (Verified)