Sample Record
Owner Lab
- Kleinfelder, Incorporated - Los Angeles
DIME Sample ID 2025-12-09-53
Project Information
| Project Identifiers | Project ID: 214649 DEA: 07316004 EFIS: 0715000194 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-14-60.70 |
| Award Date | 02/07/2023 |
| Closeout Date | Not set |
| Work Description | REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES. |
| Location Description | ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE. |
| QA Service Level | 1 (Verified on 01/29/2020) |
Sample Information
| Sample Taken Date | 12/09/2025 | Sample Unique Key | 53 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/10/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Lean Concrete Base |
| The quantity of what the sample constitutes | 300 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Justin | Last name of sampler or witnessed by | Gordon |
| Title of sampler | Field Technician | Telephone number of sampler | 909-657-1716 |
| Laboratory sample identification | 25-3858 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Atkinson Portable Plant - Lancaster | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 12622-LCB-11 |
|---|---|---|---|
| The truck number from where the sample was collected | 9 | The batch plant ticket number from where the sample was collected | 9 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2025-12-09-53-1 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | Jeffrey Diaz, Kleinfelder, Incorporated - Los Angeles | 12/16/2025 | 01/05/2026 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-12-09-53-1 CTM 521-June 2020