Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-11-09-5
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 11/09/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/28/2017 |
| Sample type | Quality Assurance | A brief description of the sample | 7/8 A325 Assembly |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
| Title of sampler | QA Inspector | Telephone number of sampler | 6616185971 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | St Louis Screw Bolt | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-245-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0095157, TT0095158 |
|---|---|---|---|
| Heat Number(s) | 10435920, 10442560 | Nut Mfg. Lot Number(s) | 23849-75063409 |
| Washer Mfg. Lot Number(s) | D3436 | Bolt Specification | A325 |
| Bolt Length(s) | 2 1/4", 3 1/4", | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | Mechanical Galvanizing |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 040948 / M4536, BM0437 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue | |
| Washer Inner Diameter(s) |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2017-11-09-5-1 ASTM F606-14a (Verified)
DIME Test ID: 2017-11-09-5-2 ASTM F606-14a (Verified)
DIME Test ID: 2017-11-09-5-3 ASTM F606-14a (Verified)
DIME Test ID: 2017-11-09-5-4 ASTM F606-14a (Verified)
DIME Test ID: 2017-11-09-5-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-11-09-5-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-14 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-19 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-20 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-21 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-22 ASTM B499-14 (Verified)
DIME Test ID: 2017-11-09-5-23 ASTM E18-15 (Verified)
DIME Test ID: 2017-11-09-5-24 ASTM E18-15 (Verified)
DIME Test ID: 2017-11-09-5-25 ASTM E18-15 (Verified)
DIME Test ID: 2017-11-09-5-26 ASTM E18-15 (Verified)