Sample Record

Owner Lab

  • Construction Testing Services

DIME Sample ID 2025-11-19-52

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Sample Information

Sample Taken Date11/19/2025 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/20/2025
Sample typeQuality Control A brief description of the sample#4 Doulbe Barrel Zap Couplers
The quantity of what the sample constitutes8 Coupler Assemblies From where was the sample collectedJob Site
First name of sampler or witnessed byJohn Last name of sampler or witnessed byHiner
Title of sampler Telephone number of sampler
Laboratory sample identification291299 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAssociated Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#4 Coupler Model04DBZA
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)5254 Rebar Heat Number(s)1201071701
Rebar Size 2 Coupler Unique IDSB-17-02

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-11-19-52-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Jon Garland, Construction Testing Services11/21/202512/03/2025
Yes
12/03/2025Public - Test Data Visible
2025-11-19-52-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)Jon Garland, Construction Testing Services11/21/202512/03/2025
Yes
12/03/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
20353_L301429_11-19-2025_L-Steel_Double Barrel Zap Screwlok Couplers_No4s_Lap Splice_Lots 1-2_JG_DVpdf12/03/2025   Info

Test File Attachments


DIME Test ID: 2025-11-19-52-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2025-11-19-52-2 CTM 670-December 2013 (Verified)