Sample Record
Owner Lab
- CT HQ - Sacramento Materials Management Branch Field Office
DIME Sample ID 2017-11-01-6
Project Information
| Project Identifiers | Project ID: 99999 DEA: 0322222 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 11/01/2017 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
| Sample type | Quality Control | A brief description of the sample | Bin 5 |
| The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Dime | Last name of sampler or witnessed by | Test |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Test | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | NA |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Natural Sand | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | SNC Wade Pit - Wadsworth, NV | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
JMF Information
| HMA Design ID | JMF3512-2017-1-5202 | Date Created | 12/22/2017 |
|---|---|---|---|
| Submittal |
Show (18)
JMF3511-6-2017-1 Submittal Authorized For Use| JMF3513-2017-1 JMF3511-6-2017-2 Submittal Completeness Review Failed JMF3511-6-2017-3 Submittal Authorized For Use| JMF3513-2018-43 JMF3511-6-2018-14 Submittal Accepted for Verification JMF3511-6-2018-15 Submittal Accepted for Verification| JMF3513-2018-9 JMF3511-6-2018-29 Submittal Completeness in Review JMF3511-6-2018-33 Submittal Accepted for Verification| JMF3513-2018-28 JMF3511-6-2018-53 Submittal Accepted for Verification| JMF3513-2018-39 JMF3511-6-2018-55 Submittal Completeness in Review JMF3511-6-2018-56 Submittal Accepted for Verification| JMF3513-2018-40 JMF3511-6-2018-57 Submittal Accepted for Verification JMF3511-6-2018-58 Submittal Accepted for Verification| JMF3513-2020-96 JMF3511-6-2019-132 Submittal Completeness in Review JMF3511-6-2020-166 Submittal Accepted for Verification| JMF3513-2024-50 JMF3511-6-2020-202 Submittal Accepted for Verification| JMF3513-2020-130 JMF3511-6-2020-278 Submittal Accepted for Verification| JMF3513-2021-36 JMF3511-6-2020-296 Submittal In Progress JMF3511-6-2021-49 Submittal Accepted for Verification| JMF3513-2024-51 |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2017-11-01-6-1 AASHTO T27-14 (Verified)