Sample Record

DIME Sample ID 2017-10-24-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212143
DEA: 101F1604
EFIS: 1016000107
DIST-CO-RTE-PM10-MER-33,5-R16.6
Award Date05/01/2017
Closeout Date03/29/2018
Work DescriptionBRIDGE REPAIR
Location DescriptionMERCED COUNTY IN SANTA NELLA AT ROUTE 33/5 SEPARATION
QA Service Level1 (Verified on 07/20/2017)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date10/24/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing10/24/2017 Sample typeQuality Control
A brief description of the sample11 bar-lock coupler The quantity of what the sample constitutes8
From where was the sample collectedJob Site First name of sampler or witnessed byYe
Last name of sampler or witnessed byYang Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Rebar
Transportation Laboratory (TL) NumberC06001468 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size11 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)74101369, MM16106575 Rebar Heat Number(s)SE14104354
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-10-24-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/201710/26/2017
Yes
11/02/2017Service SplicePublic - Test Data Visible
2017-10-24-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/201710/26/2017
Yes
11/02/2017Service SplicePublic - Test Data Visible
2017-10-24-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory10/26/201710/26/2017
Yes
11/02/2017Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-10-24-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-24-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-10-24-3-3 CTM 670-December 2013 (Verified)