Sample Record

Owner Lab

  • CT D06 - Millbrook Field Laboratory

DIME Sample ID 2025-10-31-17

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000343
DEA: 061E7304
EFIS: 0622000093
DIST-CO-RTE-PM06-FRE-41-R25.3
Award Date08/20/2024
Closeout DateNot set
Work DescriptionPREFABRICATED BUILDING, WROUGHT IRON FENCE AND GATE.
Location DescriptionFRESNO COUNTY IN FRESNO AT MCKINLEY AVENUE
QA Service Level1 (Verified on 05/29/2024)

Sample Information

Sample Taken Date10/31/2025 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/03/2025
Sample typeAcceptance A brief description of the sampleConcrete for CIDH
The quantity of what the sample constitutes6 cy From where was the sample collectedJob Site
First name of sampler or witnessed byGerzon Last name of sampler or witnessed byCeja
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCALPORTLAND Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number163459D
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected263609
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into conveyor chute to loader bucket Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-10-31-17-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersGurjeet Litt, CT D06 - Millbrook Field Laboratory11/28/202511/28/2025
Yes
11/28/2025Required strenght 3600 psi @28 daysPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-10-31-17-1 CTM 521-June 2020 (Verified)