Sample Record

DIME Sample ID 2025-10-02-49

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1001796
DEA: 021K5404
EFIS: 0224000119
DIST-CO-RTE-PM02-SHA-44-R26.94/R27.62
Award Date05/02/2028
Closeout DateNot set
Work DescriptionWest Shingletown Shoulder Widening and Rumble Strips
Location DescriptionIn Shasta County at Shingletown from 1.0 Mile West to 0.2 Mile west of Wilson Hil Road
QA Service Level1 (Verified on 10/28/2025)

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

Sample Information

Sample Taken Date10/02/2025 Sample Unique Key49
Date that the sample was received by the laboratory/organization performing the testing10/02/2025 Sample typePreliminary
A brief description of the sample2 Bags Sand Silt Rock and Soil The quantity of what the sample constitutesStructural Section Recommendation
From where was the sample collectedSource First name of sampler or witnessed byDerek
Last name of sampler or witnessed bySerna Title of samplerMREA
Telephone number of sampler Laboratory sample identificationD80072
Linked DIME Sample ID The fabricator/manufacturer/facility nameDistrict 2 Lab
Transportation Laboratory (TL) Number897620 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedShoulder at SHA 44, PM 27.5
Where the material sample would have been placed if not sampled

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-10-02-49-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesDacota Mei , CT D02 - Redding Northern Regional Laboratory10/08/202510/29/2025
Yes
10/29/2025Public - Test Data Visible
2025-10-02-49-2CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerJosh Murphy , CT D02 - Redding Northern Regional Laboratory10/14/202510/29/2025
Yes
10/29/2025R=40Public - Test Data Visible
2025-10-02-49-3CTM 217-June 2011: Method of Test for Sand EquivalentDacota Mei , CT D02 - Redding Northern Regional Laboratory10/14/202510/29/2025
Yes
10/29/2025SE=20Public - Test Data Visible
2025-10-02-49-4CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and WaterJosh Murphy , CT D02 - Redding Northern Regional Laboratory10/15/202510/29/2025
Yes
10/29/2025pH=6.30, p=6129.Ω∙cmPublic - Test Data Visible
2025-10-02-49-5ASTM D2487-17: Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)Colt Sweeny, CT D02 - Redding Northern Regional Laboratory10/28/202510/29/2025
Yes
10/29/2025A silty sand with gravel, (SM)gPublic - Test Data Visible
2025-10-02-49-6CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)Josh Murphy , CT D02 - Redding Northern Regional Laboratory10/16/202510/29/2025
Yes
10/29/2025PI=14%Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-10-02-49-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2025-10-02-49-2 CTM 301-March 2000 (Verified)
DIME Test ID: 2025-10-02-49-3 CTM 217-June 2011 (Verified)
DIME Test ID: 2025-10-02-49-4 CTM 643-April 2020 (Verified)
DIME Test ID: 2025-10-02-49-5 ASTM D2487-17 (Verified)
DIME Test ID: 2025-10-02-49-6 CTM 204-June 2010 (Verified)