Sample Record

DIME Sample ID 2025-07-24-105

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214649
DEA: 07316004
EFIS: 0715000194
DIST-CO-RTE-PM07-LA-14-60.70
Award Date02/07/2023
Closeout DateNot set
Work DescriptionREHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES.
Location DescriptionROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE.
QA Service Level1 (Verified on 01/29/2020)

Owner Lab

  • Alta Vista Solutions - Whittier

Sample Information

Sample Taken Date07/24/2025 Sample Unique Key105
Date that the sample was received by the laboratory/organization performing the testing07/24/2025 Sample typeQuality Assurance
A brief description of the sampleJPCP 6x12 Cylinders The quantity of what the sample constitutes840 CY
From where was the sample collectedJob Site First name of sampler or witnessed byEriberto
Last name of sampler or witnessed byAragon Title of samplerMaterials Tester
Telephone number of sampler8186240301 Laboratory sample identification25-2381
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCI-12622-1
The truck number from where the sample was collectedTruck or Ticket 84 The batch plant ticket number from where the sample was collectedLoad 84
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampledJobsite
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-07-24-105-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteEriberto Aragon, Alta Vista Solutions - Whittier07/24/202510/22/2025
Yes
10/22/2025Public - Test Data Visible
2025-07-24-105-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodEriberto Aragon, Alta Vista Solutions - Whittier07/24/202510/22/2025
Yes
10/22/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-07-24-105-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2025-07-24-105-2 CTM 504-June 2010 (Verified)