Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2025-10-15-33
Project Information
| Project Identifiers | Project ID: 1001065 DEA: 070Y1304 EFIS: 0724000134 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-101-25.9/30.6 |
| Award Date | 05/22/2025 |
| Closeout Date | Not set |
| Work Description | MAINLINE INDIVIDUAL SLAB REPLACEMENT. |
| Location Description | VENTURA COUNTY IN VENTURA FROM 0.1 MILE WEST OF TELEPHONE RD UNDERCROSSING TO VENTURA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/01/2025) |
Sample Information
| Sample Taken Date | 10/15/2025 | Sample Unique Key | 33 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/22/2025 |
| Sample type | Verification | A brief description of the sample | 3/4" HMA-A-SP- R25 0.50% LAS |
| The quantity of what the sample constitutes | 24 boxes of HMA, 4 Bags of comb Aggs, 2 Bags of RAP | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Cesar | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulvan Saticoy | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035,91-19-0020 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt Cut at Vulcan Materials- Oro Grande | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2025-10-15-33-1 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | R.A. , CT D08 - Fontana Southern Regional Laboratory | 10/23/2025 | 10/28/2025 | No | Combined Virgin Aggregate Gradation | |||
| 2025-10-15-33-2 | AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity) | Friday Ofoegbu, CT D08 - Fontana Southern Regional Laboratory | 10/24/2025 | 10/28/2025 | No | ||||
| 2025-10-15-33-3 | AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity) | R.G. , CT D08 - Fontana Southern Regional Laboratory | 10/24/2025 | 10/28/2025 | No | ||||
| 2025-10-15-33-4 | AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler) | Julius Esonwune, CT D08 - Fontana Southern Regional Laboratory | 10/26/2025 | 10/28/2025 | No | ||||
| 2025-10-15-33-5 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | R.G. , CT D08 - Fontana Southern Regional Laboratory | 10/26/2025 | 10/28/2025 | No | ||||
| 2025-10-15-33-6 | AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles) | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 10/25/2025 | 10/28/2025 | No | ||||
| 2025-10-15-33-7 | AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles) | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 10/25/2025 | 10/28/2025 | No | ||||
| 2025-10-15-33-8 | ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles) | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 10/25/2025 | 10/28/2025 | No | ||||
| 2025-10-15-33-9 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 10/26/2025 | 11/03/2025 | No | RAP Gradation After Ignition | |||
| 2025-10-15-33-10 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | David Padilla, CT D08 - Fontana Southern Regional Laboratory | 10/27/2025 | 11/03/2025 | No | Combined Virgin Aggregate Gradation W/ RAP Gradation Correction Factor |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-10-15-33-1 AASHTO T27-14
DIME Test ID: 2025-10-15-33-2 AASHTO T84-14
DIME Test ID: 2025-10-15-33-3 AASHTO T85-13
DIME Test ID: 2025-10-15-33-4 AASHTO T96-02r10
DIME Test ID: 2025-10-15-33-5 AASHTO T176-08
DIME Test ID: 2025-10-15-33-6 AASHTO T304-11
DIME Test ID: 2025-10-15-33-7 AASHTO T335-09r13
DIME Test ID: 2025-10-15-33-8 ASTM D4791-10
DIME Test ID: 2025-10-15-33-9 CTM 202-November 2011
DIME Test ID: 2025-10-15-33-10 CTM 202-November 2011