Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2025-10-13-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000403
DEA: 120K91U4
EFIS: 1222000031
DIST-CO-RTE-PM12-ORA-91-R9.2/R11.4
Award Date01/03/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING
QA Service Level1 (Verified on 08/19/2024)

Sample Information

Sample Taken Date10/13/2025 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/14/2025
Sample typeQuality Control A brief description of the sample4x8 cylinders
The quantity of what the sample constitutes12 From where was the sample collectedJob Site
First name of sampler or witnessed byAndrew Last name of sampler or witnessed bySolis
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identificationMix 556300 Set 1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAssociated Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier00-0000
Structure nameRW and SW 191 STA 193+00 - 195+42 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number556300
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected0
Concrete batch plant The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedRW 199 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-10-13-8-1CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteAndrew Solis, G3 Quality, Incorporated - Cerritos10/13/202510/15/2025
Yes
11/19/2025
2025-10-13-8-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodAndrew Solis, G3 Quality, Incorporated - Cerritos10/13/202510/15/2025
Yes
11/19/2025
2025-10-13-8-3CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteAndrew Solis, G3 Quality, Incorporated - Cerritos10/13/202510/15/2025
Yes
11/19/2025
2025-10-13-8-4CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteAndrew Solis, G3 Quality, Incorporated - Cerritos10/13/202510/15/2025
Yes
11/19/2025
2025-10-13-8-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersIsaac Vasquez, G3 Quality, Incorporated - Cerritos10/20/202510/29/2025
Yes
11/19/2025
2025-10-13-8-6CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersIsaac Vasquez, G3 Quality, Incorporated - Cerritos10/27/202510/29/2025
Yes
11/19/2025
2025-10-13-8-7CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersIsaac Vasquez, G3 Quality, Incorporated - Cerritos11/10/202511/11/2025
Yes
11/19/2025

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-10-13-8-1 CTM 518-June 2010 (Verified)
DIME Test ID: 2025-10-13-8-2 CTM 504-June 2010 (Verified)
DIME Test ID: 2025-10-13-8-3 CTM 556-January 2018 (Verified)
DIME Test ID: 2025-10-13-8-4 CTM 557-June 2020 (Verified)
DIME Test ID: 2025-10-13-8-5 CTM 521-June 2020 (Verified)
DIME Test ID: 2025-10-13-8-6 CTM 521-June 2020 (Verified)
DIME Test ID: 2025-10-13-8-7 CTM 521-June 2020 (Verified)