Sample Record

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2025-09-23-7

Project Information

Project IdentifiersProject ID: 1000403
DEA: 120K91U4
EFIS: 1222000031
DIST-CO-RTE-PM12-ORA-91-R9.2/R11.4
Award Date01/03/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING
QA Service Level1 (Verified on 08/19/2024)

Sample Information

Sample Taken Date09/23/2025 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing09/29/2025
Sample typeQuality Assurance A brief description of the sample#6 welded hoop 5'-2"
The quantity of what the sample constitutes426 From where was the sample collectedManufacturer
First name of sampler or witnessed byAdrian Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler2137133499
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL159-119-25 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4150983
Hoop Manufacturer Lot Number(s)1-3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyCMC Rebar San Bernardino Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-09-23-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory10/08/202510/08/2025
Yes
10/08/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-09-23-7-1 CTM 670-December 2013 (Verified)