Sample Record

Owner Labs

  • Kwik Bond Polymers
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2025-08-25-83

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000514
DEA: 043Y5904
EFIS: 0423000264
DIST-CO-RTE-PM04-CC-680,680-1.47/24.26
Award Date05/23/2025
Closeout DateNot set
Work DescriptionPLACE POLYESTER CONCRETE OVERLAY, GRIND BRIDGE DECK, AND PAVE SLOPE.
Location DescriptionCONTRA COSTA COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/13/2024)

Sample Information

Sample Taken Date08/25/2025 Sample Unique Key83
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/26/2025
Sample typeQuality Control A brief description of the sample1 gallon can / PPC 1121 RESIN
The quantity of what the sample constitutes2 Tankers From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification25-156 Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) Number177KBP
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ5H01047
Batch numberAZ5H01047 Mix numberAZ5H01047

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-08-25-83-1ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational ViscometerGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory08/28/202510/23/2025
Yes
10/23/2025Accepted supplier's result.Public - Test Data Visible
2025-08-25-83-2ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related ProductsGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory08/28/202510/23/2025
Yes
10/23/2025Accepted supplier's result.Public - Test Data Visible
2025-08-25-83-3ASTM D2369-Jul10: Standard Test Method for Volatile Content of CoatingsGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory08/28/202510/23/2025
Yes
10/23/2025Accepted supplier's result.Public - Test Data Visible
2025-08-25-83-4ASTM D638-Dec14: Standard Test Method for Tensile Properties of PlasticsLaura Bird, CT HQ - Sacramento Concrete Testing Laboratory08/28/202510/23/2025
Yes
10/23/2025Accepted supplier's result.Public - Test Data Visible
2025-08-25-83-5CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and StructuresGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory09/04/202510/23/2025
Yes
10/23/2025Accepted supplier's result.Public - Test Data Visible
2025-08-25-83-6SCAQMD 309-91-Feb93: Determination of Static Volatile EmissionsGilberto Gonzalez, CT HQ - Sacramento Concrete Testing Laboratory09/03/202510/23/2025
Yes
10/23/2025Accepted supplier's result.Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-08-25-83-1 ASTM D2196-Feb15 (Verified)
DIME Test ID: 2025-08-25-83-2 ASTM D1475-Nov13 (Verified)
DIME Test ID: 2025-08-25-83-3 ASTM D2369-Jul10 (Verified)
DIME Test ID: 2025-08-25-83-4 ASTM D638-Dec14 (Verified)
DIME Test ID: 2025-08-25-83-5 CTM 551-August 2012 (Verified)
DIME Test ID: 2025-08-25-83-6 SCAQMD 309-91-Feb93 (Verified)