Sample Record

DIME Sample ID 2025-08-28-27

Project Information

Project IdentifiersProject ID: 993595
DEA: 042Q5504
EFIS: 0419000024
DIST-CO-RTE-PM04-SOL-12-7.9/14.1
Award Date02/14/2025
Closeout DateNot set
Work DescriptionRHMA OVERLAY, REPLACE CULVERTS, BRIDGE RAILS, AND MEDIAN BARRIERS.
Location DescriptionSOLANO COUNTY NEAR SUISUN CITY FROM 0.2 MILE EAST OF LAWLER RANCH PARKWAY TO 0.5 MILE EAST OF SHILOH ROAD
QA Service Level1 (Verified on 02/22/2022)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/28/2025 Sample Unique Key27
Date that the sample was received by the laboratory/organization performing the testing09/02/2025 Sample typeQuality Assurance
A brief description of the sampleZap Screwlok SL coupler The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byNA
Last name of sampler or witnessed byNA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBridge Deck
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBar Splice Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelZap Screwlok SL
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)4000027988 Rebar Heat Number(s)3500041857
Rebar Size 2 Coupler Unique IDSL-21-02

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-08-28-27-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory09/04/202509/04/2025
Yes
09/04/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM5 Couplers rev 2025-08-28-27pdf09/04/2025   Info
26001338.005A_20250828_25-SAC-00921_Metal_DIME ID#2025-08-28-27pdf09/04/2025   Info

Test File Attachments


DIME Test ID: 2025-08-28-27-1 CTM 670-December 2013 (Verified)