Sample Record
DIME Sample ID 2025-08-28-19
Project Information
| Project Identifiers | Project ID: 1000501 DEA: 081J6104 EFIS: 0818000102 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-215-40.5/42.7 |
| Award Date | 11/05/2024 |
| Closeout Date | Not set |
| Work Description | INDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE. |
| Location Description | RIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING |
| QA Service Level | 1 (Verified on 09/02/2024) |
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
Sample Information
| Sample Taken Date | 08/28/2025 | Sample Unique Key | 19 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/29/2025 | Sample type | Quality Control |
| A brief description of the sample | 6x12 | The quantity of what the sample constitutes | 3 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | BONNIE |
| Last name of sampler or witnessed by | B | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 1081-828 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | VANGUARD | |
| Transportation Laboratory (TL) Number | 1081-828 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | * |
|---|---|---|---|
| The truck number from where the sample was collected | 03 | The batch plant ticket number from where the sample was collected | 6253 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | JOB | Where the material sample would have been placed if not sampled | NB215 NEAR MLK BLVD |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-08-28-19-1 ASTM C39-10 (Verified)