Sample Record

Owner Labs

  • CT D01 - Boyd Road Field Laboratory
  • CT D01 - District 1 Materials Laboratory

DIME Sample ID 2025-08-12-46

Project Information

Project IdentifiersProject ID: 994751
DEA: 010C5004
EFIS: 0112000292
DIST-CO-RTE-PM01-HUM-36-11.3/34.6
Award Date03/02/2023
Closeout DateNot set
Work DescriptionProject Name: Bridge Rail Replacement - 3 Bridges
Location DescriptionHely Creek, Little Larabee Creek and Butte Creek Bridge.
QA Service Level1 (Verified on 04/27/2023)

Sample Information

Sample Taken Date08/12/2025 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/13/2025
Sample typeQuality Assurance A brief description of the samplePCC with slag and air entrainment.
The quantity of what the sample constitutes11 CY From where was the sample collectedJob Site
First name of sampler or witnessed bySam Last name of sampler or witnessed byKaplan
Title of samplerASR Telephone number of sampler707-496-0826
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMercer Fraser Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameLittle Larabe Creek Bridge Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberMF CL 1 .40 SLAG AE
The truck number from where the sample was collected683 The batch plant ticket number from where the sample was collected111152
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete dischanged from the truck Where the material sample would have been placed if not sampledAbutment 1 wingwall
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-08-12-46-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersJamie Kelley, CT D01 - District 1 Materials Laboratory08/19/202508/19/2025
Yes
08/19/20251 cylinder break at 7 days, 8/19/25Public - Test Data Visible
2025-08-12-46-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersJamie Kelley, CT D01 - District 1 Materials Laboratory09/09/202509/09/2025
Yes
09/09/20252 cylinder-28 day breaks on 9/9/25. If cylinders exceed 5000 psi, break 3rd cylinder. If average strength is below 5000 psi, reserve 3 remaining cylinders for 42 day break.Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-08-12-46-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2025-08-12-46-2 CTM 521-June 2020 (Verified)