Sample Record

DIME Sample ID 2025-08-12-1

Project Information

Project IdentifiersProject ID: 215365
DEA: 120Q9704
EFIS: 1218000010
DIST-CO-RTE-PM12-ORA-405-0/11.4
Award Date07/27/2023
Closeout DateNot set
Work DescriptionI-405 improvement project from I-5 to Harbor Boulevard including extend pavement life, improve safety, enhance traffic operation, and incorporate Intelligent Transportation Systems (ITS).
Location DescriptionOrange County I-405 PM 0 - 11.4
QA Service Level1 (Verified on 07/01/2021)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date08/12/2025 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing08/14/2025 Sample typeQuality Assurance
A brief description of the sample2" Flat Washer The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byAlexis
Last name of sampler or witnessed byMillan Title of samplerQA
Telephone number of sampler(909)756-9960 Laboratory sample identification
Linked DIME Sample ID2025-07-23-1 The fabricator/manufacturer/facility nameMadden Bolt
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL191-010-25
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)NA
Heat Number(s)42507860 Nut Mfg. Lot Number(s)NA
Washer Mfg. Lot Number(s)0425-622 Bolt SpecificationNA
Bolt Length(s)NA Nut SpecificationNA
Washer SpecificationASTM F436 FinishASTM F2329
Diameter/Size2" Bolt Mfg. Lot NumberNA
Rocap Test Requirement(s)NA Lubricant Requirements(s)NA
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-08-12-1-1ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/202508/19/2025
Yes
08/19/2025Public - Test Data Visible
2025-08-12-1-2ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/202508/19/2025
Yes
08/19/2025Public - Test Data Visible
2025-08-12-1-3ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/202508/19/2025
Yes
08/19/2025Public - Test Data Visible
2025-08-12-1-4ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/202508/19/2025
Yes
08/19/2025Public - Test Data Visible
2025-08-12-1-5ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/202508/19/2025
Yes
08/19/2025Public - Test Data Visible
2025-08-12-1-6ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/19/202508/19/2025
Yes
08/19/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-08-12-1-1 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-08-12-1-2 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-08-12-1-3 ASTM B499-09r21 (Verified)
DIME Test ID: 2025-08-12-1-4 ASTM E18-20 (Verified)
DIME Test ID: 2025-08-12-1-5 ASTM E18-20 (Verified)
DIME Test ID: 2025-08-12-1-6 ASTM E18-20 (Verified)