Sample Record
Owner Lab
- CT HQ - Sacramento Asphalt Binder Laboratory
DIME Sample ID 2025-05-18-24
Project Information
| Project Identifiers | Project ID: 212861 DEA: 101H2804 EFIS: 1017000190 |
|---|---|
| DIST-CO-RTE-PM | 10-STA-5-10.7/25.5 |
| Award Date | 02/06/2024 |
| Closeout Date | Not set |
| Work Description | BRIDGE DECK OVERLAY WITH POLYESTER CONCRETE, REPLACE APPROACH SLABS & JOINT SEALS IN STANISLAUS COUNTY ON STATE ROUTE 5 FROM FINK ROAD UC TO KHALSA ROAD UC. |
| Location Description | STANISLAUS AND MERCED COUNTIES. |
| QA Service Level | 1 (Verified on 03/23/2020) |
Sample Information
| Sample Taken Date | 05/18/2025 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/30/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 HMASP |
| The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
| First name of sampler or witnessed by | T | Last name of sampler or witnessed by | Trefz |
| Title of sampler | MREA | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vernalis | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 0436011 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | 1 |
| Sublot number | 10 | Tank number | |
| Time of sample | HMA Supplier | Teichert Vernalis | |
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | Yes |
| Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| 2025-05-18-24 | 09/17/2025 | Info |
Test File Attachments
DIME Test ID: 2025-05-18-24-1 AASHTO T315-24 (Verified)