Sample Record
Owner Lab
- Precast Unlimited Inc.
DIME Sample ID 2025-07-30-4
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 1000279 DEA: 023H70U4 EFIS: 0223000161 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-299-15.0/25.7 |
| Award Date | 08/09/2024 |
| Closeout Date | Not set |
| Work Description | RHMA-G, HMA (TYPE A), COLD PLANE AC, & SOLDIER PILE RETAINING WALL. |
| Location Description | TRINITY COUNTY NEAR DEL LOMA FROM 1.0 MILE EAST OF TRINITY RIVER BRIDGE NO.05-0006 TO 0.1 MILE WEST OF PRAIRIE CREEK ROAD |
| QA Service Level | 1 (Verified on 04/30/2024) |
Sample Information
| Sample Taken Date | 07/30/2025 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/30/2025 |
| Sample type | Quality Control | A brief description of the sample | 9 4x8 concrete cylinders |
| The quantity of what the sample constitutes | 1 CU/FT | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Donald | Last name of sampler or witnessed by | Juneman |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | JF Shea Construction, Shasta Redi-Mix, Redding, CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CT752SLA50 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 99746 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Back of Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-07-30-4-1 ASTM C1064-17 (Verified)
DIME Test ID: 2025-07-30-4-2 ASTM C143-20 (Verified)
DIME Test ID: 2025-07-30-4-3 ASTM C231-17a (Verified)
DIME Test ID: 2025-07-30-4-4 ASTM C39-21 (Verified)
