Sample Record

Owner Labs

  • CT HQ - QASI Bay Area Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2025-07-30-1

Project Information

Project IdentifiersProject ID: 993595
DEA: 042Q5504
EFIS: 0419000024
DIST-CO-RTE-PM04-SOL-12-7.9/14.1
Award Date02/14/2025
Closeout DateNot set
Work DescriptionRHMA OVERLAY, REPLACE CULVERTS, BRIDGE RAILS, AND MEDIAN BARRIERS.
Location DescriptionSOLANO COUNTY NEAR SUISUN CITY FROM 0.2 MILE EAST OF LAWLER RANCH PARKWAY TO 0.5 MILE EAST OF SHILOH ROAD
QA Service Level1 (Verified on 02/22/2022)

Sample Information

Sample Taken Date07/30/2025 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/05/2025
Sample typeVerification A brief description of the sampleF1544 Gr 105 Heavy Hex Bolt
The quantity of what the sample constitutes28 From where was the sample collectedFabricator
First name of sampler or witnessed byChris Last name of sampler or witnessed byDsouza
Title of sampler Telephone number of sampler9493852715
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUniveral Industrial Sales Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)58063033-07 Nut Mfg. Lot Number(s)NA
Washer Mfg. Lot Number(s) Bolt SpecificationASTM F1544 Grade 105
Bolt Length(s)20" Nut SpecificationNA
Washer SpecificationNA FinishHot Dip Galvanized
Diameter/Size1 1/4" Bolt Mfg. Lot Number65325
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-07-30-1-1ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202508/26/2025
Yes
08/26/2025Public - Test Data Visible
2025-07-30-1-2ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202508/26/2025
Yes
08/26/2025Public - Test Data Visible
2025-07-30-1-3ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/26/202508/26/2025
Yes
08/26/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM3 Fasteners rev 2025-07-30-1pdf08/25/2025   Info
2025-07-30-1_Anchor Bolts Test Report - F1554pdf08/25/2025   Info

Test File Attachments


DIME Test ID: 2025-07-30-1-1 ASME B1.2-83r17 (Verified)
DIME Test ID: 2025-07-30-1-2 ASTM B499-09r21 (Verified)