Sample Record

DIME Sample ID 2025-07-28-7

Project Information

Project IdentifiersProject ID: 994928
DEA: 010F9704
EFIS: 0116000111
DIST-CO-RTE-PM01-MEN-162-29.18/30.27
Award Date04/19/2023
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 07/18/2023)

Owner Labs

  • CT HQ - Vallejo Field Laboratory
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date07/28/2025 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing07/30/2025 Sample typeVerification
A brief description of the sampleHCR Couplers The quantity of what the sample constitutes150
From where was the sample collectedManufacturer First name of sampler or witnessed byKevin
Last name of sampler or witnessed byCarpenter Title of samplerQA
Telephone number of sampler4156081742 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBuild-Tex
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormB24-110-25
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3500039074 Head Manufacturer Lot Number(s)Unknown
Rebar Size#11 Headed Bar Model NameHRC670L
Size of HeadReduced Size - 4x Head Connection TypeThreaded
Head ShapeCircular Rebar ManufacturerNucor
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique ID4FG-17-01

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-07-28-7-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory08/14/202508/14/2025
Yes
08/14/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
RE_ Stroer & Graff Job #2306 - Covelo SR 162 - Mill Certs (MTR's) for CIDH Pile Reinforcementpdf07/29/2025   Info
M0811-0893 Dime Number 2025-7-28-7pdf08/13/2025   Info

Test File Attachments


DIME Test ID: 2025-07-28-7-1 ASTM A970-18 (Verified)