Sample Record
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2025-07-22-4
Project Information
| Project Identifiers | Project ID: 995193 DEA: 07356604 EFIS: 0719000026 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-605-R10.2/20.2 |
| Award Date | 04/04/2024 |
| Closeout Date | Not set |
| Work Description | LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY. |
| Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION |
| QA Service Level | 1 (Verified on 10/03/2023) |
Sample Information
| Sample Taken Date | 07/22/2025 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/25/2025 |
| Sample type | Quality Assurance | A brief description of the sample | A706 GR.60 #6 x 4'-8"x 5'-5" Oval Hoops |
| The quantity of what the sample constitutes | 110 hoops | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Alexis | Last name of sampler or witnessed by | Millan |
| Title of sampler | QA | Telephone number of sampler | (909)756-9960 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar Company | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L191-005-25 | Structure unique identifier | 07-356604 |
| Structure name | LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 219925, 1202068856 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 4'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade, Nucor |
| Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-07-22-4-1 CTM 670-December 2013 (Verified)