Sample Record

DIME Sample ID 2017-08-01-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Award Date11/16/2015
Closeout Date07/11/2022
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
QA Service Level1 (Verified on 03/07/2016)

Owner Labs

  • CT HQ - QASI Bay Area Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date08/01/2017 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing08/02/2017 Sample typeVerification
A brief description of the sample4 A775 Epoxy coated rebar The quantity of what the sample constitutes1 truck load
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byFlygare Title of samplerCA METS QA Inspector
Telephone number of sampler801-669-2984 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWestern Coating
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormB76-123-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)4062485
Rebar Epoxy Batch Number(s)3416421 Rebar Coating SpecificationASTM A775
Rebar Size (#)4 Rebar Coating ColorGreen
Rebar ManufacturerCMC Rebar CoaterWestern Coating
Rebar Powder ManufacturerAxalta Release Number36370
Quality Assurance CodeUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2017-08-01-6-1ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017
Yes
08/11/2017Public - Test Data Visible
2017-08-01-6-2ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/03/2017
Yes
08/11/2017Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-08-01-6-1 ASTM A775-07b-re14 (Verified)