Sample Record

Owner Labs

  • CT HQ - QASI Los Angeles Field Office
  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2025-07-07-8

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Sample Information

Sample Taken Date07/07/2025 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/11/2025
Sample typeQuality Assurance A brief description of the sample#7 3'-2" Welded Hoops
The quantity of what the sample constitutes362 From where was the sample collectedFabricator
First name of sampler or witnessed byAdrian Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler2137133499
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL159-095-25 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)9007653,9007693
Hoop Manufacturer Lot Number(s)1,3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-07-07-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Steven Paine, CT HQ - Sacramento Structural Materials Testing Laboratory07/23/202507/23/2025
Yes
07/23/2025Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
COVER SHEET TM5 Welded Hoops 2025-07-07-8pdf07/23/2025   Info
26001338.005A_20250707_25-SAC-00711_Metal_DIME ID#2025-07-07-8pdf07/23/2025   Info
26001338.005A_20250707_25-SAC-00710_Metal_DIME ID#2025-07-07-8pdf07/23/2025   Info

Test File Attachments


DIME Test ID: 2025-07-07-8-1 CTM 670-December 2013 (Verified)