Sample Record

Owner Lab

  • CT D02 - Redding Northern Regional Laboratory

DIME Sample ID 2025-06-26-58

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000117
DEA: 020J0104
EFIS: 0219000044
DIST-CO-RTE-PM02-TEH-99-4.2/4.8
Award Date07/11/2024
Closeout DateNot set
Work DescriptionPLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location DescriptionTEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date06/26/2025 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2025
Sample typeProduction Start-Up A brief description of the sample1 Bag RAP
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD79923B Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River, Orland Transportation Laboratory (TL) Number858140
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceOrland Plant
Aggregate Size Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Combined Gradation Report Information

Combined Gradation Report IdBin IndexDime Test Id
2025-07-5: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP22025-06-26-58-1

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2025-06-26-58-1AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)Dacota Mei , CT D02 - Redding Northern Regional Laboratory07/02/202507/02/2025
Yes
07/02/2025Public - Test Data Visible
2025-06-26-58-2AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)Dacota Mei , CT D02 - Redding Northern Regional Laboratory06/30/202507/02/2025
Yes
07/02/2025Pbr (uncorrected)=5.99%Public - Test Data Visible
2025-06-26-58-3AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)Josh Ferency, CT D02 - Redding Northern Regional Laboratory06/30/202507/02/2025
Yes
07/02/2025Gmmr=2.556Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2025-06-26-58-1 AASHTO T30-19 (Verified)
DIME Test ID: 2025-06-26-58-2 AASHTO T308-10 (Verified)
DIME Test ID: 2025-06-26-58-3 AASHTO T209-12 (Verified)