Sample Record
Owner Lab
- CT D09 - Bishop Field Laboratory
DIME Sample ID 2025-06-30-1
Project Information
| Project Identifiers | Project ID: 1000541 DEA: 09374704 EFIS: 0918000019 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-168,395-17.6/18.3,114.9/117.8 |
| Award Date | 02/21/2025 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), MINOR CONCRETE, AND LIGHTING. |
| Location Description | INYO COUNTY IN AND NEAR BISHOP ON ROUTE 395 FROM 0.1 MILE SOUTH OF JAY STREET TO BARLOW LANE AND ON ROUTE 168 FROM PIONEER LANE TO ROUTE 395 |
| QA Service Level | 1 (Verified on 09/02/2024) |
Sample Information
| Sample Taken Date | 06/30/2025 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/30/2025 |
| Sample type | Acceptance | A brief description of the sample | Class 2 Aggregate Base |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
| First name of sampler or witnessed by | Josh | Last name of sampler or witnessed by | Hubartt |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | CB1 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Bishop,CA Landfill | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Bishop,CA Landfill |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Recycled Class II Base | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | Stockpile at the plant. | |
| Where the material sample would have been placed if not sampled | Sidewalk | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2025-06-30-1-1 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | Derek Carrington, CT D09 - Bishop Field Laboratory | 07/01/2025 | 07/01/2025 | No | AB-1 Grindings | |||
| 2025-06-30-1-2 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | Derek Carrington, CT D09 - Bishop Field Laboratory | 07/01/2025 | 07/01/2025 | No | Class II Agg Base Grindings Gradation | |||
| 2025-06-30-1-3 | CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer | Derek Carrington, CT D09 - Bishop Field Laboratory | 07/01/2025 | 07/01/2025 | No | Class II Agg Base Grindings | |||
| 2025-06-30-1-4 | CTM 229-June 2011: Method of Test for Durability Index | Derek Carrington, CT D09 - Bishop Field Laboratory | 07/01/2025 | 07/01/2025 | No | AB-1 Grindings |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2025-06-30-1-1 AASHTO T176-08
DIME Test ID: 2025-06-30-1-2 AASHTO T27-14
DIME Test ID: 2025-06-30-1-3 CTM 301-March 2000
DIME Test ID: 2025-06-30-1-4 CTM 229-June 2011